JLG 1200SJP Service Maintenance Manual page 466

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Flash
DTC
Sequence
Code
33154
33
154
33155
33
155
33156
33
156
33157
33
157
33158
33
158
33159
33
159
33160
33
160
33161
33
161
33162
33
162
33163
33
163
33164
33
164
33165
33
165
33166
33
166
33167
33
167
33168
33
168
33169
33
169
33173
33
173
33174
33
174
6-90
Table 6-6. Diagnostic Trouble Code Chart
Fault Message
LIFT DOWN AUX VALVE - OPEN CIRCUIT
LIFT DOWN AUX VALVE - SHORT TO BATTERY
TOWER LIFT APU VALVE - SHORT TO GROUND
TOWER LIFT APU VALVE - OPEN CIRCUIT
TOWER LIFT APU VALVE - SHORT TO BATTERY
MAIN LIFT ENABLE VALVE - SHORT TO GROUND
MAIN LIFT ENABLE VALVE - OPEN CIRCUIT
MAIN LIFT ENABLE VALVE - SHORT TO BATTERY
TOWER TELESCOPE APU VALVE - STUCK OPEN
TOWER TELESCOPE ENABLE VALVE - STUCK OPEN
TOWER TELESCOPE ENABLE VALVE - SHORT TO GROUND
TOWER TELESCOPE ENABLE VALVE - OPEN CIRCUIT
TOWER TELESCOPE ENABLE VALVE - SHORT TO BATTERY
PVG ENABLE VALVE - SHORT TO GROUND
PVG ENABLE VALVE - OPEN CIRCUIT
PVG ENABLE VALVE - SHORT TO BATTERY
RESTRICTED TO TRANSPORT - AXLE LOCKOUT VALVE - SHORT TO BATTERY
OR OPEN CIRCUIT
RESTRICTED TO TRANSPORT - BRAKE - SHORT TO BATTERY OR OPEN CIR-
CUIT
Fault Description
There is an Open Circuit to the
Lift Down Auxiliary Valve.
There is a Short to Battery to the
Lift Down Auxiliary Valve.
There is a Short to Ground to the
Tower Lift APU Valve.
There is an Open Circuit to the
Tower Lift APU Valve.
There is a Short to Battery to the
Tower Lift APU Valve.
There is a Short to Ground to the
Main Lift Enable Valve.
There is an Open Circuit to the
Main Lift Enable Valve.
There is a Short to Battery to the
Main Lift Enable Valve.
The Tower Telescope APU Valve
is Stuck Open
The Tower Telescope Enable
Valve is Stuck Open
There is a Short to Ground to the
Tower Telescope APU Valve.
There is an Open Circuit to the
Tower Telescope APU Valve.
There is a Short to Battery to the
Tower Telescope APU Valve.
There is a Short to Ground to the
PVG Valve.
There is an Open Circuit to the
PVG Valve.
There is a Short to Battery to the
PVG Valve.
There is a Short to Battery or an
Open Circuit to the Axle Lockout
Valve.
There is a Short to Battery or an
Open Circuit to the Brake.
– JLG Lift –
Check
- Gravity Lift Down equipped vehi-
cles only.
- Gravity Lift Down equipped vehi-
cles only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
3121142

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350sjp