JLG 1200SJP Service Maintenance Manual page 402

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
PARAMETER
SUBMENU
(DISPLAYED ON
(DISPLAYED ON ANALYZER 2
ANALYZER 1ST LINE)
GROUND
U. LIFT UP XXX%
MODE:
U. LIFT DN XXX%
SWING XXX%
BASKET LVL XXX%
BASKET ROT XXX%
MAIN TELE XXX%
TOWER TELE XXX%
T. LIFT UP XXX%
T. LIFT DN XXX%
JIB (U/D) XXX%
JIB (L/R) XXX%
GEN SET/WELDER:
ENGINE XXXX RPM
6-26
Table 6-3. Personality Ranges/Defaults
ND
LINE)
Displays/adjusts fixed main lift up speed
Displays/adjusts main lift down speed
Displays/adjusts fixed swing speed
Displays/adjusts fixed basket level speed
Displays/adjusts fixed basket rotate speed
Displays/adjusts fixed main telescope speed
Displays/adjusts fixed tower telescope speed
Not displayed if TOWER TELE=NO
Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO
Displays/adjusts fixed tower lift down speed
Not displayed if TOWER LIFT=NO
Displays/adjusts jib lift speed
Not displayed if JIB = 0
Displays/adjusts jib swing speed
Displayed if JIB = 2
Control generator/welder RPM. Not displayed if
GEN SET/WELDER = 0
DESCRIPTION
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
1200-2800
– JLG Lift –
DEFAULT VALUES
RANGE
WHEN SETTING SPEEDS)
1200
1350
60
60
60
60
60
60
75
75
75
75
60
60
100
100
100
100
100
100
60
60
70
70
1800
1800
TIME RANGE (SEC) (SEE
SECTION 6.10 FOR
MACHINE ORIENTATION
1200S
1350S
4150453-F