5-5
DIAGNOSTIC MODE
DETAILS
(CONT.)
March 2015
Loading Report for Previous Batch of Shortening
If no products have a "failed to detect" rate of more than 5%, the control-
ler shows:
"D9: LOADING"
"D9: LOOKED OK"
"D9: PREVIOUS OIL"
Otherwise, for each product that has more than 5% of loads in which
the controller failed to detect the drop point, the following message is
displayed:
"D9: PREVIOUS OIL,"
"D9: IRREGULAR"
"D9: LOADING"
"D9: FOR 6% OF"
"D9: "BRK-FIL"
D 10: Non-Standard Program Items Report
The last section in the Diagnostic Report identifies how many program-
mable settings have been altered from their original, factory default
settings.
For each of the various program modes, the controller either reports that
"all settings match original values" or reports "N items do not match
original values". This report makes it easy to see if any cook parameters
or other settings have been changed from CFA settings.
Some programming items may have been changed from original values
under the direction of CFA corporate headquarters. In some cases, a
controller should have values that don't match original values. A report
that "all items match original values" could actually be an indication that
something isn't set right.
Keep in mind also that the number of such "approved" alterations might
be different for different versions of software.
If all product cook settings match the original, factory default values, the
controller displays the following message:
"10: ALL PROD'S"
"10: MATCH"