INFORMATION MODE
DETAILS
(CONT.)
March 2015
7. PREV DAY - SUN
Press ▼ to step through the following data. During each step, press
to choose the day of the week, of the past 7 days.
Function
Day this data was recorded for
Time of day last heat-up was completed
Peak heat-up rate (°F/Sec) - last heat-up
Was that day's last heat-up acceptable?
Heat cap. status (based on last 4 ht-ups)
Number of monitored heat-ups that day
Number of slow heat-ups
Max heat time 270°F to 310°F that day
Lowest "peak rate" - that day's heat-ups
Max voltage that day (when fryer on)
Min voltage that day (when fryer on)
No. of "low voltage" warnings generated
Maximum amp draw that day
Minimum amp draw that day
No. of "low amps" warnings that day
Non-cooking time (hh:mm) fryer was on
Oil wear accumulated that day
Total number of Cook Cycles that day
Number of cycles started before ready
No. cycles quit early, (0:11 or more remaining)
No. cycles beeped *DONE* 21 sec or more
Individual product cook counts
Individual product "not detected" counts
Individual product "slow cook" counts
Individual product "overloaded"
(During steps 7V through 7Y, press the product buttons (or Manual Prog)
to see data on individual product items.)
Press
to continue onto 7-DAY TOTALS log.
43
Model CFE-415, 427
Display Example
7A. DATE
APR-8
7B. LAST HEAT 8:15P
7C. LAST RATE 0.88
7D. LAST OK? YES
7E. HEAT CAP GOOD
7F. HEAT-UPS
7
7G. SLOW HT'S
0
7H. MAX HT TM 1:11
7I. MIN RATE 0.67
7J. MAX VOLT 102%
7K. MIN VOLT 98%
7L. LO VOLT'S
0
7M. MAX AMPS
35
7N. MIN AMPS
34
7O. LO AMP'S
0
7P. IDLE HRS 7:09
7Q. OIL WEAR
39
7R. TOT CK'S
18
7S. NOT RDY'S
2
7T. QUIT 11+
1
7U. DONE 21+
3
7V. Px CK CT
12
7W. Px NO DET
1
7X. Px SLO CT
0
7Y. Px OVRLD
1