5-5
DIAGNOSTIC MODE
DETAILS
(CONT.)
March 2015
Loading Report for Today
If no products have a "failed to detect" rate of more than 5%, the control-
ler shows:
"D9: LOADING"
"D9: LOOKS OK"
"D9: TODAY"
Otherwise, for each product that has more than 5% of loads in which
the controller failed to detect the drop point, the following message is
displayed:
"D9: IRREGULAR"
"D9: LOADING"
"D9: FOR 8% OF"
"D9: "FILET" (
"D9: TODAY"
Loading Report for Present Batch of Shortening
The data for this batch of shortening does not yet include Cook Cycles
from today.
If no products have a "failed to detect" rate of more than 5%, the control-
ler shows:
"D9: LOADING"
"D9: LOOKS OK"
"D9: THIS OIL"
Otherwise, for each product that has more than 5% of loads in which
the controller failed to detect the drop point, the following message is
displayed:
"D9: FOR THIS OIL,"
"D9: IRREGULAR"
"D9: LOADING"
"D9: FOR 12% OF"
"D9: "NUG-STRP" (
73
Model CFE-415, 427
Product Name )