INFORMATION MODE
DETAILS
(CONT.)
March 2015
12. OUTP B-S-H*
This mode displays the status of components and outputs. If the output
signal is detected, an identifying letter is displayed (see below), followed
by an "*". If the output is off, "_" is displayed.
H = Heat output
If heat is on, "H*" shows in display. If heat is off, "H_" shows in dis-
play. If controls senses a problem with the heat output, "H*" shows in
display, with the "*" flashing.
Press ▼ to view the "amps" status of output.
"H√" in the display means the amps are good. A flashing "X" behind the
H means a problem exists.
Press ▼ to view the No Connect/Ground ("NC/GD") status of the out-
put. This monitors a possible problem with the relays on the output PC
board.
"H√" in the display means everything on the output PC board is good. A
flashing "X" behind the H means a problem exists.
Press ▼ to view the outputs and inputs (see step 10) together.
Press
to continue onto the POT TMP reading.
13. POT TMP
This step shows the present shortening temperature. The display shows
"13. POT TMP (temp.)".
Press
to continue onto the LEVEL TEMPERATURE reading.
14. LEVEL TEMPERATURE
This step shows the present level probe temperature.
Press
to continue onto the PROTECTION TEMPERATURE read-
ing.
15. PROTECTION TEMPERATURE
This step shows the present PROTECTION probe temperature.
Press
to continue onto the CPU TEMPERATURE reading.
48
Model CFE-415, 427