Problem
Shortening will not heat
Shortening heating slowly
Shortening heating slowly
(continued)
March 2015
HEATING OF SHORTENING SECTION
Cause
Blown fuse or tripped
•
circuit breaker at supply
box
Faulty cord and plug
•
Faulty PC board
•
Faulty or tripped high
•
limit; "E10"
Drain valve open; "E15"
•
Possible faulty probe;
•
"E6"
Possible faulty contactor
•
Faulty POWER switch
•
Faulty drain switch;
•
"E15"
Low or improper amps
•
Low or improper
•
voltage
Wire(s) loose
•
Faulty PC board
•
Weak or burnt out
•
elements (elec. model)
Burnt or charred
•
connectors
Faulty contactor
•
60
Model CFE-415, 427
Correction
Reset breaker or replace fuse
•
Check cord and plug and check power at
•
wall receptacle
Have control panel checked
•
Reset high limit per Operating Components
•
Section; if high limit doesn't reset, have it
checked
Close drain valve
•
Have temperature probe checked
•
See Diagnostic Modes D 4; if "CHECK
•
COILS, CONTACTORS AND WIRING"
shows on display, have contactors and
wiring checked
See Information Mode 11 and check to
•
see if the input code is present; if not,
have fryer checked by a certified service
technician
See Infomation Mode 17 for present
•
amperage; or see Information Modes
4, 5, 6, 7, 8, 9, and 10 for more information
on this problem. Diagnostic Mode D 4 gives
present day's heating performance
See Diagnostic Modes D 3 & D 4
•
for present day's voltage and heating
performance; or see Information Modes 4,
5, 6, 7, 8, 9, 10 and 15 for more information
on this problem
Have wires tightened
•
Have control panel checked
•
See Diagnostic Modes D 4; see if "CHECK
•
COILS, CONTACTORS AND WIRING"
shows on display; if so, have fryer checked
by a certified service technician