3-3
DIAGNOSTIC MODE
AND SPECIAL
FUNCTIONS
(CONT.)
March 2015
Information Mode
This mode gathers and stores historic information on the fryer and
Operator performance. Press
"*INFO MODE*"
shows on display. Press
the steps and press
to view the statistics within each step.
Information Mode is intended for technical use, but the
Operator can view the following information:
E-LOG - last 10 errors and time they occurred
1.
P-LOG - time of last 10 power-ups
2.
HEAT-UPS - time of day and maximum heating rate (°/second) for
3.
the last 10 heat-ups
LEFT COOK DATA - information on the last Cook Cycle, using the
4.
left timer button
RIGHT COOK DATA - information on the last Cook Cycle, using
5.
the right timer button
TODAY'S DATA - data since the start of day (not including the last
6.
Cook Cycle)
PREV-DAY-SUN - creates a log of the last 7 days, using the infor-
7.
mation in TODAY'S DATA.
7-DAY TOTALS-totals the information from the last 7days
8.
OIL DATA - information on the current shortening, not including
9.
today's cooking information
PREV OIL DATA - information on last batch of shortening
10.
INP - provides test of fryer inputs
11.
OUTP - shows the state of heater
12.
POT TMP - temperature of shortening
13.
CPU TMP - temperature of PC board
14.
ANALOG - status of controller's a-to-d converter
15.
AC VOLTS - status of the line voltage to fryer
16.
AMPS (Electric models only) - the present amp readings to heaters.
17.
See Information Mode Details Section for more details.