Henny Penny CFE-415 Operator's Manual page 46

Open fryer (electric)
Hide thumbs Also See for CFE-415:
Table of Contents

Advertisement

4-1
INFORMATION MODE
DETAILS
(CONT.)
March 2015
5. RIGHT COOK DATA
Press ▼ button to start viewing the cook data.
Function
Time of last Cook Cycle started
Product (last product cooked)
Ready? (fryer ready before start?)
Drop detect status
Drop adjust (real time seconds)
Cook time adj (clock adjust)
Actual elapsed cook time (seconds)
Stopped: Time remaining, or secs past done
"Slow cook" for this cycle?
Overloaded? (Bad batch)
Avg Temp during Cook Cycle
Max voltage during Cook Cycle
Min voltage during Cook Cycle
Max amps during Cook Cycle
Min amps during Cook Cycle
Press
to continue onto the TODAYS DATA.
6. TODAY'S DATA (automatically resets each day)
Press ▼ to step through the following data:
Function
Today's Date
Time of day last heat-up was completed
Peak heat-up rate(°F/Sec)for last heat-up
Was last heat-up acceptable?
Heat Cap. status (based on last 4 ht-ups)
Number of monitored heat-ups today
Number of slow heat-ups
Max time to heat 270°F to 310°F today
Lowest "peak rate" for today's heat-ups
Maximum voltage today (when fryer on)
Minimum voltage today (when fryer on)
No.of "low voltage" warnings generated
Maximum amp draw today
Minimum amp draw today
Number of "low amps" warnings today
Non-cooking time (hh:mm) fryer was on
Oil Wear accumulated so far today
Total number of Cook Cycles today
Number of cycles started before Ready
No. cycles quit early, 0:11 or more rem.
No. cycles beeped *DONE *21 sec or more
Individual product cook counts
Individual product "not detected" counts
Individual product "slow cook" counts
Ind. product "overloaded"
(During steps 6V through 6Y, press the product buttons (or Manual Prog)
to see data on individual product items)Press
DAY-SUN log.
42
Model CFE-415, 427
Display Example
5A. STARTED 10.25A
5B. PRODUCT -1-
5C. READY?
YES
5D. DETECT X NO
5E. DROP ADJ T-10
5F. CK TM ADJ -13
5G. ACT TIME 2:23
5H. STOP DONE+1
5I. SLOW?
NO
5J. OVRLD? NO
5K. AVG TMP 343°F
5L. MAX VOLT 99%
5M. MIN VOLT 97%
5N. MAX AMPS 33
5O. MIN AMPS 33
Display Exa
6A. DATE APR-12
6B.LAST HEAT 9:45A
6C. LAST RATE 0.82
6D. LAST OK? YES
6E.HEAT CAP GOOD
6F. HEAT-UPS 2
6G. SLOW HT'S 0
6H. MAX HT TM 1:17
6I. MIN RATE 0.82
6J. MAX VOLT 99%
6K. MIN VOLT 95%
6L. LO VOLT'S 0
6M. MAX AMPS 35
6N. MIN AMPS 33
6O. LO AMP'S 0
6P. IDLE HRS 1:23
6Q. OIL WEAR 3
6R. TOT CK'S 11
6S. NOT RDY'S 2
6T. QUIT 11+ 0
6U. DONE 21+ 1
6V. Px CK CT 2
6W. Px NO DET 0
6X. Px SLO CT 0
6Y. Px OVRLD 0
to continue onto PREV-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfe-427

Table of Contents