Henny Penny CFE-415 Operator's Manual page 21

Open fryer (electric)
Hide thumbs Also See for CFE-415:
Table of Contents

Advertisement

3-3
DIAGNOSTIC MODE
AND SPECIAL
FUNCTIONS
(CONT.)
March 2015
Manual Mode
This allows the Operator to quickly program a time and press tem-
perature for nonstandard products that are not on the menu card.
This is to be a temporary setting and disables most of the advanced
features of the controls. To enter
Manual Mode:
Once out of the Melt Cycle, press
1.
Use
to set cook time.
2.
Press
and use
3.
Press
to start Manual Mode. Display shows.
4.
and you start a Cook Cycle by pressing
Press
to exit Manual Mode.
5.
Status Mode
Pressing
during idle time, allows Operator to view:
a. The temperature of the shortening
b. The temperature setpoint and any offset
c. The average shortening temperature during last Cook
Cycle
d. The rate of temperature rise or fall
e. Date and Time
Pressing
during a Cook Cycle allows the Operator to
view:
a. The temperature of shortening, plus the degrees and
rate the load compensation has affected the Cook Cycle
(slows down or speeds up the timer)
b. The cooking step, the time left in Cook Cycle, and
setpoint temperature
c. Average shortening temperature in Cook Cycle so far
d. The rate of temperature rise or fall
e. Date and Time
After 5 seconds, the control exits the Status Mode and the open fryer
returns to normal operation.
17
Model CFE-415, 427
then
.
to set temperature.
"MANUAL"
.