5-4
TROUBLE SHOOTING
GUIDE
(CONT.)
Problem
With POWER switch in ON
position, fryer is completely
without power
Filter motor runs but pumps
shortening slowly
FILTER PUMP switch on,
motor does not run
Motor hums but will not pump
March 2015
POWER SECTION
Cause
•
Open circuit
FILTER SYSTEM SECTION
•
Pump clogged
•
Filter line
connection loose
•
Solidified shortening
in lines
•
Defective FILTER
PUMP switch
•
Defective motor
•
Motor thermal
protector tripped
•
Clogged lines or
pump removed
59
Model CFE-415, 427
Correction
•
Check to see if fryer is plugged in
•
Check wall circuit breaker or fuse
•
Have a qualified service technician
check power supply and POWER
switch
•
Have pump cleaned
•
Tighten all filter line loose
connections
•
Clear all filter lines of solidified
shortening
•
Have switch checked
•
Have motor checked
•
Reset thermal protector per Filter
Pump Motor Filter Protector Section
•
Have pump and lines and cleaned
•
Have pump seal, rotor and rollers
replaced