Henny Penny CFE-415 Operator's Manual page 63

Open fryer (electric)
Hide thumbs Also See for CFE-415:
Table of Contents

Advertisement

5-4
TROUBLE SHOOTING
GUIDE
(CONT.)
Problem
With POWER switch in ON
position, fryer is completely
without power
Filter motor runs but pumps
shortening slowly
FILTER PUMP switch on,
motor does not run
Motor hums but will not pump
March 2015
POWER SECTION
Cause
Open circuit
FILTER SYSTEM SECTION
Pump clogged
Filter line
connection loose
Solidified shortening
in lines
Defective FILTER
PUMP switch
Defective motor
Motor thermal
protector tripped
Clogged lines or
pump removed
59
Model CFE-415, 427
Correction
Check to see if fryer is plugged in
Check wall circuit breaker or fuse
Have a qualified service technician
check power supply and POWER
switch
Have pump cleaned
Tighten all filter line loose
connections
Clear all filter lines of solidified
shortening
Have switch checked
Have motor checked
Reset thermal protector per Filter
Pump Motor Filter Protector Section
Have pump and lines and cleaned
Have pump seal, rotor and rollers
replaced