H3DR-G
Time Ranges
Star-delta transfer time
Star operation time
p
Time scale: x 1 s
setting
tti
Time scale: x 10 s
Ratings
Rated supply voltage (see note)
Operating voltage range
Power reset
Power consumption
Control outputs
Characteristics
Accuracy of operating time
Setting error
Star-delta transfer time
Reset voltage
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Humidity class
Life expectancy
EMC
Enclosure ratings
Weight
Note: The reset voltage is the residual voltage allowed from the power supply when returning the Timer to the status that existed prior to
operation.
96
0.05 sec
1 to 12 s
10 to 120 s
100 to 240 VAC (50/60 Hz), 48 VAC (50/60 Hz), 24 VAC/DC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
100 to 240 VAC: approx. 11 VA; 48 VAC: approx. 1.2 VA;
24 VAC/DC: approx. 0.9 VA (AC), approx. 0.45 W (DC)
Contact output: 5 A at 250 VAC, resistive load (cos% = 1)
!1% FS max.
!10% FS !0.05 s max.
Accuracy: !25% FS + 5 ms max.
10% max. of rated supply voltage (10 V max. for 100 to 240 VAC)
!0.5% FS max.
!2% FS max.
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals) for 100 to 240 VAC,
1 kV for 24 VAC/DC, 48 VAC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
for 100 to 240 VAC,
1.5 kV for 24 VAC/DC, 48 VAC
!1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:
100 ns/1 &s, 1-ns rise)
Malfunction:4 kV
Destruction: 8 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in three directions
2
Destruction: 980 m/s
(100G) each in three directions
2
Malfunction:98 m/s
(10G) each in three directions
Operating:--10"C to 55"C (with no icing)
Storage: --25"C to 65"C (with no icing)
Operating: 35% to 85%
DIN 40 040: G
Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Emission Enclosure:
EN55011 Group 1 class A
Emission AC Mains:
EN55011 Group 1 class A
Immunity ESD:
IEC801-2:
Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance:
Immunity Burst:
IEC801-4:
IEC: IP40
Approx. 110 g
0.1 sec
0.25 sec
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
ENV50141: 10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
H3DR-G
0.5 sec