Omron H3CR-A Manual page 220

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H2A
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Note: The front panel of the timer is color-coded to identify the following supply voltage classifications:
100, 110 V:
Blue
200, 220 V:
Red
Other classes: Black
Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Motor life expectancy
Approved standards
Weight
Engineering Data
Load current (A)
220
100, 110, 200, or 220 VAC (50 Hz), 100/110, 200/220 VAC (60 Hz)
85% to 110% of rated supply voltage
Approx. 3 VA
Standard type: 2 A at 250 VAC, resistive load (cos% = 1)
!2% max. *!3% max. for the 5-s model)
!5% max.
0.3 s max.
!1% max.
!2% max.
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts,
between contact and control circuit and between) contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 16.7 Hz with 4-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 1,000 m/s
(approx. 100G)
2
Malfunction: 100 m/s
(approx. 10G) (5G for lateral shocks)
Operating: --10"C to 50"C
Operating: 45% to 85%
Mechanical: 1,000,000 operations min. (under no load at operating of 1,800 operations/hr)
Electrical:
See "Engineering Data"
20,000 hrs
UL (File No. E52800-US), CSA (File No. LR22310-US)
Approx. 170 g
H2A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents