H3DR-F
Time Ranges
Time unit
0
Setting
Time scale: x 0.1 s
Time scale: x 1 s
Note: To obtain instantaneous output, set to below 0.
Ratings
Rated supply voltage (see note)
Operating voltage range
Power reset
Power consumption
Control outputs
Note: A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
Characteristics
Accuracy of operating time
Setting error
Reset time
Reset voltage
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Humidity class
Life expectancy
EMC
Enclosure ratings
Weight
Note: The reset voltage is the residual voltage allowed from the power supply when returning the Timer to the status that existed prior to
operation.
sec
Instantaneous (see note)
0.1 to 1.2 s
1 to 12 s
1 to 12 s
10 to 120 s
100 to 240 VAC (50/60 Hz), 48 VAC (50/60 Hz), 24 VAC/DC (50/60 Hz), 12 VDC
85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models
Minimum power-opening time: 0.1 s
100 to 240 VAC: approx. 8.2 VA; 48 VAC: approx. 1.7 VA;
24 VAC/DC: approx. 1.3 VA (AC), approx. 0.6 W (DC); 12 VDC: approx. 0.4 W
Contact output: 5 A at 250 VAC, resistive load (cos% = 1)
!1% FS max. (!1% FS !10 ms max. in ranges of 1.2 s)
!10% FS !0.05 s max.
0.1 s max.
10% max. of rated supply voltage (10 V max. for 100 to 240 VAC)
!0.5% FS max. (!0.5% FS !10 ms in ranges of 1.2 s)
!2% FS max. (!2% FS !10 ms in ranges of 1.2 s)
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals) for 100 to 240 VAC
1 kV for 12 VDC, 24 VAC/DC, 48 VAC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
for 100 to 240 VAC
1.5 kV for 12 VDC, 24 VAC/DC, 48 VAC
!1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:
100 ns/1 &s, 1-ns rise)
!400 V for 12 VDC
Malfunction:4 kV
Destruction: 8 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in three directions
2
Destruction: 980 m/s
2
Malfunction:98 m/s
(10G) each in three directions
Operating:--10"C to 55"C (with no icing)
Storage: --25"C to 65"C (with no icing)
Operating: 35% to 85%
DIN 40 040: G
Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance:
Immunity Burst:
IEC: IP40
Approx. 110 g
10 s
0.1 to 1.2 min
1 to 12 min
(100G) each in three directions
EN55011 Group 1 class A
EN55011 Group 1 class A
IEC801-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
ENV50141: 10 V (0.15 to 80 MHz) (level 3)
IEC801-4:
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
H3DR-F
min
hrs
0.1 to 1.2 h
1 to 12 h
91