Omron H3CR-A Manual page 133

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H3M
Ratings
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Note: 1. Color indicators for the rated voltage are provided on the front of the Timer.
Blue: 100/110/120 VAC
Red: 200/220/240 VAC
None: Other voltages
2. With DC ratings, single-phase full-wave rectified power sources may be used.
3. 90% to 110% for 12-VDC models.
Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Note: For the timer with time range code A, add !10 ms to the respective characteristics when the time range selector switches are in the x 1 s
(0.05 to 0.5 s) position.
Engineering Data
Load current (A)
100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz),
12, 24, 48, 100, 110 VDC (see note 2)
AC: 85% to 110% of rated supply voltage
DC: 80% to 110% of rated supply voltage (see note 3)
AC: Approx. 5 VA/2 W
DC: Approx. 2 W
5 A at 250 VAC, resistive load (cos% = 1)
!1% max. (see note)
!10% max.
0.1 s max.
!1% max. (see note)
!2% max. (see note)
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 1,000 m/s
(approx. 100G)
2
Malfunction: 100 m/s
(approx. 10G)
Operating: --10"C to 50"C
Storage:
--25"C to 65"C
Operating: 35% to 85%
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
UL (File No. E41515), CSA (File No. LR22310)
Approx. 100 g
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos% = 1).
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
H3M
133