Omron H3CR-A Manual page 154

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H5CL
Operation
DIP Switch Setting
Pin no.
1, 2, 3
Time ranges
4
Display modes
5
Min. pulse width of inputs
6
Operating modes
Note: Set the DIP switch before installation and operation of the Unit. DIP switch setting changes are not effective while the power is on.
Time Ranges
1
2
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
Note: Switches 1 to 6 are all set to OFF before shipping.
Top of Timer
ON
1
2
3 4 5 6
Timer Control with Power Start
When using the H5CL with power start, short-circuit the start input and input 0-V terminals.
Operating Modes
A Mode
Signal ON-delay
Display
mode
F Mode
Accumulative Operation
Display
mode
154
Item
See table below.
Up (Increment)
20 ms
A (signal ON-delay)
3
0.001 to 9.999 s
0.01 to 99.99 s
0.1 to 999.9 s
1 to 9999 s
0 min 01 s to 99 min 59 s
0.1 to 999.9 min
0 h 01 min to 99 h 59 min
0.1 to 999.9 h
(The same switch settings apply to AC and DC models)
Power
Start
Gate
Reset
Control output
Set value
UP
0
Set value
DOWN
0
Power
Start
Gate
Reset
Control output
Set value
UP
0
Set value
DOWN
0
OFF
Down (Decrement)
1 ms
F (accumulative operation)
Time range
H5CL
ON