Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Cyclic error
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Note: The overall error, which includes repeat accuracy, setting error, and variations due to changes in voltage and temperature, is !0.01% or
!0.05 s max..
Engineering Data
Ambient Operating Temperature and Carry Current
Note that the upper limit of the ambient operating temperature lowers
when a large carry current is being applies as shown below.
Carry current AC/DC (A)
!0.01% !0.05 s max. (see note 1)
!15 s (at 25"C)
100 M$ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed
non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between control power supply circuit and contact control
output circuits, between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
2
Destruction: 300 m/s
(approx. 30G)
2
Malfunction: 100 m/s
(approx. 10G)
Operating: --10"C to 55"C
Operating: 35% to 85%
100,000 operations min. (15 A at 250 VAC, resistive load)
UL (File No. E52800), CSA (File No. LR22310), SEV
Approx. 350 g
H5L
253