Three-Dimensional Transform Operations (Menu) - Sony XVS-G1 User Manual

Multi format switcher system
Hide thumbs Also See for XVS-G1:
Table of Contents

Advertisement

For details about initial status, see "Setting Startup"
(page 282).
To return three-dimensional parameters to the initial
settings:
Press the [CLR WORK BUFR] button once.
To return all DME parameters to the initial settings:
Press the [CLR WORK BUFR] button twice. Or press
and hold the [SHIFT] button and press the [CLR
WORK BUFR] button.
Three-Dimensional Transform
Operations (Menu)
This section describes the menu for DME channel 1 as an
example.
Adjusting three-dimensional parameters
1
Open the Home > DME > Channel1 > 3D Transform
> Adjust menu (15101.11).
2
In the [Local/Global] group, select local space or
global space.
Local: Local space
Global: Global space
Both local space and global space can be selected.
3
In the [Source/Target] group, select source space or
target space.
Source: Source space
Target: Target space
Either source space or target space can be selected.
4
Set the target three-dimensional transform operation
X-axis, Y-axis, and Z-axis parameters.
When local space is selected
Press the [X] button, [Y] button, or [Z] button for
[Local], and enter a setting value in the numeric
keypad window.
When global space is selected
Press the [X] button, [Y] button, or [Z] button for
[Global], and enter a setting value in the numeric
keypad window.
To adjust parameters using the analog controls
section
Press the button for the target three-dimensional
transform operation to set, and set the [X] parameter,
[Y] parameter, and [Z] parameter in the analog
controls section.
When both local space and global space are selected,
the parameter buttons for local space are displayed on
the 1st page and the parameter buttons for global space
are displayed on the 2nd page. Set the parameters for
local space on the 1st page and the parameters for
global space on the 2nd page.
Configurable three-dimensional parameters
The parameters that can be set vary depending on the
three-dimensional transform operation buttons.
Location Size: Scale image (shrink/magnify)
Only the Z-axis in source space can be configured.
All axes in target space can be configured.
Location XYZ: Move image
All axes can be configured.
Rotation: Rotate image (rotation mode)
All axes can be configured.
Spin: Rotate image (spin mode)
All axes can be configured.
Aspect: Change image aspect ratio
Only the source space of the local space can be
configured.
Skew: Change image skew
Only the X-axis and Y-axis in the source space of the
local space can be configured.
Perspective: Change viewpoint position
Only target space can be configured.
Axis Location: Move rotation axis
Only source space can be configured.
To change parameters to the closest detent
position
Press the [Detents] button.
For details about detents, see "Detents" (page 144).
To return parameters to the initial settings
The parameters return to the initial status saved data
setting values.
The operation must be performed separately for global
space and local space.
For details about initial status, see "Setting Startup"
(page 282).
To return three-dimensional parameters to the initial
settings:
Press the [Clear 3D Parameter] button.
To return all DME parameters to the initial settings:
Press the [Clear All Parameters] button.
150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents