Chapter 22 Cross-Point Setup; Creating A Cross-Point Assign Table; Creating The Main Table; Creating Tables 1 To 14 - Sony XVS-G1 User Manual

Multi format switcher system
Hide thumbs Also See for XVS-G1:
Table of Contents

Advertisement

Cross-Point Setup
Creating a Cross-Point
Assign Table
You can create a main table (Main) and up to 14 other
tables (Table1 to Table14) as cross-point assign tables.
You can configure the video signal and key signal
combinations in the main table.

Creating the Main Table

You can assign a signal pair consisting of a video signal
and a key signal to each cross-point button number.
You can also assign the same signals to multiple button
numbers to duplicate the assignment.
1
Open the Home > Setup > Xpt Assign > Main, V/K
Pair Assign menu (19102.21).
The V/K pair number (cross-point button number),
video signal source name and number, and key signal
source name and number are displayed.
2
Select the target button number to set.
To select and set multiple button numbers, place a
check mark beside the target button numbers to set.
To select and set all button numbers, place a check
mark in the Select All checkbox.
3
Press the [Edit] button.
To set the video signal, press the [Edit] button for
[Video].
To set the key signal, press the [Edit] button for [Key].
The [Select Source] window appears.
4
Set the button for the source signal to assign to the on
state.
Select a tab to change the type of signal to display.
[Input] tab: Input signals
[B/W/COLBKG] tab: Black, white, and color
background signals
Chapter
[DME/FM/CLIP] tab: DME monitor, frame
memory, and clip player output signals
[PP/ME Out] tab: Switcher bank output signals
Note
Input signals 45 to 48 cannot be used.
5
Press [OK].
When a signal is not assigned
On the [B/W/COLBKG] tab of the [Select Source]
window, select the [N/A] button.
The signal will not be switched even when the cross-point
button is pressed.
To delete a button number setting
Select the target button number to delete and press the
[Delete] button.
The settings for all the button numbers not deleted move
up in sequence.
To insert a button number setting
Select the button number at the insertion position and press
[Insert].
A button number is inserted and the settings of all other
buttons are shifted by one.
To return to the initial settings
Press the [Default Recall] button, check the message, then
press [OK].

Creating Tables 1 to 14

You can assign the V/K pair signals configured in the main
table to cross-point button numbers.
1
Open the Home > Setup > Xpt Assign > Table Button
Assign menu (19102.31).
2
Display the target table to set.
Select a tab to change the table (Table1 to Table14) to
display.
3
Select the target button number to set.
301
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents