Section 9: Doing the Water Leak Test
[1] If SEISMIC BRACKETS are needed and if the PROCESSOR is in its final position, install the SEISMIC
BRACKETS at this time. See the instructions provided with the SEISMIC BRACKET KIT 261413.
[2] Check that all 3 DRAIN VALVES are closed.
[3] Fill the FIXER and DEVELOPER TANKS with water until the level of the water is at the OVERFLOW
WEIRS. Water will go down the DRAIN LINES when the TANKS are full.
Caution
To prevent spills or splashes into other TANKS or onto electrical parts:
• Check that the SIDE ACCESS PANELS are installed.
• Pour the water into the TANK at the non-drive end of the PROCESSOR.
• Do not pour water onto the RACKS.
Filling the TANKS for the Water Leak Test
Figure 46
54
FIXER TANK
OVERFLOW
WEIRS
DEVELOPER
TANK
H130_0152HCA
H130_0152HA
September 1995 – 981088