Warning
You must install all SAFETY COVERS which were removed for access.
[2] Install the COVERS and PANELS. See
Removing the WATER SOLENOID VALVE
BACK ACCESS PANEL
[1] Remove the BACK ACCESS PANEL and the MULTILOADER BULKHEAD PANEL to gain access to the VALVE.
[2] See the illustration to remove the VALVE.
Removing the POPPET VALVES from the REPLENISHMENT PUMPS
Important
• Observe the direction of the POPPET VALVES and the location of the O-RINGS before you remove them.
• For easier access to the POPPET VALVES, you may want to remove the REPLENISHMENT PUMP.
POPPET VALVE (2)
H104_0167BCA
H104_0167BA
7C8285 – 28JAN98
Page
5.
MULTILOADER BULKHEAD PANEL
FITTING (2)
O-RING (2)
VALVE
developer
BODY
REPLENISHMENT
PUMP
WATER SOLENOID
fixer
REPLENISHMENT
PUMP
Plumbing
H104_0588BCA
H104_0588BA
25