Power supply: Han Q4/2 socket (connection for X1)
Note
When you use the "connector monitoring" function, you have to connect pin 11 to pin 12 in
the connector.
Motor connection Han Q8/0 pin (connection for X2)
See brake variants
1)
M200D AS-Interface Standard
Manual, 08/2014, A5E02548958A/RS-AA/004
Socket
Assignment
1
Phase L1
2
Phase L2
3
Phase L3
4
N
11
Connector monitoring
12
Connector monitoring
PE (yellow/green)
Pin
Assignment
1
L1 out
2
N
1)
3
L3 out
4
Brake L1 (switched)
5
Temperature sensor
6
Brake L3 (direct)
7
L2 out
8
Temperature sensor
PE (yellow/green)