Program
Program Name
No.
80-03-04
DTMF Tone Receiver Setup - Max. Detect Level
80-03-05
DTMF Tone Receiver Setup - Forward Twist Level 0 ~ 9 (1 dB ~ 10 dB)
80-03-06
DTMF Tone Receiver Setup - Backward Twist
Level
80-03-07
DTMF Tone Receiver Setup - ON Detect Time
80-03-08
DTMF Tone Receiver Setup - OFF Detect Time
80-04-01
Call Progress Tone Detector Setup - Detection
Level
80-04-04
Call Progress Tone Detector Setup - No Tone
Time
Operation
Refer to the individual features listed in the Related Features section above in this feature.
Features and Specifications Manual
Input Data
0 ~ 15
DTMF Tone 0 = 0 dBm (0) to - 15
dBm (15)
DTMF Tone 1 = - 5 dBm (0) to -
20 dBm (15)
DTMF Tone 2 = - 10 dBm (0) to -
25 dBm (15)
DTMF Tone 3 = - 15 dBm (0) to -
30 dBm (15)
DTMF Tone 4 = - 20 dBm (0) to -
35 dBm (15)
DTMF Tone 5 = - 25 dBm (0) to -
40 dBm (15)
DTMF Tone 6 = - 30 dBm (0) to -
45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
1 ~ 255 (15 + 15 ms ~ 3825 ms)
1 ~ 255 (15 + 15 ms ~ 3825 ms)
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (30 + 30 ~ 7680 ms)
(0 = not detect)
1 ~ 255 = 60 ~ 7680 ms
The formula is 30 + 30N
When set to N = 1, it means 30
+ 30
1 = 60.
*
When set to N = 255, it means
30 + 30
*
255 = 7680.
SL2100
Default
Refer to the Program-
ming Manual for the
default values.
S
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
1-777

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents