NEC SL2100 Features And Specifications Manual page 260

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Feature Examples
Digital Trunk Clocking Examples:
If PRI and BRI exist, the system synchronizes with PRI. In this example, the PRI in slot01 was the first
priority to synchronize with the carrier; therefore, it is the PLO synchronization source.
D
If multiple BRIs exist and becomes no PRI exists, the system chooses the first BRI that synchronized
with the carrier. In this example, the BRI in slot02 synchronized with the carrier first and became the
PLO synchronization source.
In this scenario, the PRI was the clocking source until it went down. There are no other BRIs in the
system. The CPU now becomes the PLO synchronization source.
Guide to Feature Programming
Refer to
ISDN Compatibility on page
Operation
Refer to the related features for details.
1-246
Main Chassis
082U+2BRIDB (BRI)
Figure 1-9 Digital Trunk Clocking Example 1
Main Chassis
082U+2BRIDB (BRI)
Figure 1-10 Digital Trunk Clocking Example 2
Main Chassis
CPU
Figure 1-11 Digital Trunk Clocking Example 3
1-534.
082U+1PRIDB (PRI)
082U+1PRIDB (PRI)
082U+1PRIDB (PRI)
Digital Trunk Clocking
ISSUE 1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents