2.7 Structure and functions of the basic program
Control/Status signals
A shared feature of the control and status signals is that they are bit fields. The basic
program updates them at the start of OB1.
The signals can be subdivided into the following groups:
• General signals
• Mode-groupspecific signals such as operating modes
• Channelspecific signals such as program and feed modifications
Axis- and spindlespecific signals such as feed disable
Auxiliary and G functions
The auxiliary and G functions have the following characteristics:
• Transfer to the PLC is blocksynchronous (referred to a parts program block)
• Transfer is acknowledgecontrolled.
• The acknowledgment times have an immediate effect on the execution time of NC blocks
The value range is presented in the table below:
Function
G function
M word
S word
T word
D word
H word
F word
relative number, transferred for each G group
1)
corresponding STEP 7 format (24-bit mantissa, 8-bit exponent)
2)
The M, S, T, H, D and F values sent by the NCK are output together with the accompanying
change signals to the CHANNEL DB interface via the auxiliary/G functions (see
documentation "Lists of SINUMERIK 840D, 810D"). The function value and the extended
address are transferred to the appropriate data word. The accompanying modification signal
is activated to 1 for one PLC cycle. When the modification signal is reset, the
acknowledgment is passed to the NCK. The acknowledgment of highspeed auxiliary
functions is given by the basic program immediately the basic program detects the auxiliary
function.
In addition to distribution of the auxiliary and G functions, selected signals are processed as
described below.
52
containing auxiliary functions requiring acknowledgment.
Structure
1. Value
M group
Spindle no.
Magazine
no.
-
H group
Axis No.
Value range
2. Value
1. Value
G function
M word
99
S word
6
T word
99
D word
99
H word
99
F word
18
Basic logic functions: PLC Basic program powerline (P3 pl)
Data type
2. Value
1. Value
255
1)
99.999.999
Word
Floating
Word
point
2)
65535
Word
255
Byte
Floating
Word
point
Floating
Word
point
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2. Value
Byte
DWord
DWord
Word
Byte
DWord
DWord