Siemens SINUMERIK 840D sl Function Manual page 1391

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

END_VAR
Description of formal parameters
The table below lists all formal parameters of the PUT function.
Signal
Req
NumVar
Addr1 to Addr8
Unit 1 to Unit 8
Column 1 to Column
8
Line 1 to Line 8
Error
Done
State
SD1 to
SD8
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
SD1 :
SD2 :
SD3 :
SD4 :
SD5 :
SD6 :
SD7 :
SD8 :
Typ
Type
e
I
BOOL
I
INT
I
ANY
I
BYTE
I
WORD
I
WORD
A
BOOL
BOOL
Q
WORD
Q
I/O
ANY
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
Range of values
1 to 8
(corresponds to use of
Addr1 to Addr8)
[DBName].[VarName]
P#Mm.n BYTE x...
P#DBnr.dbxm.n BYTE x
Detailed description
2.12 Block descriptions
Remark
Job start with positive signal edge
Number of variables to be written
Variable identifiers from
NC Var selector
Area address, optional for
variable addressing
Column address, optional for
variable addressing
Line address, optional for variable
addressing
Negative acknowledgment of job
or execution of job impossible
Job successfully executed
See error identifiers
Data to be written
117