Startup and synchronization of NCK PLC
Loading the basic program
The basic program must be loaded with the S7 tool when the PLC is in the Stop state. This
ensures that all blocks in the basic program will be initiated correctly the next time they are
called. An undefined state may otherwise develop on the PLC (e.g., all PLC LEDs flashing).
Startup
The synchronization of NCK and PLC is performed during startup. The system and user data
blocks are checked for integrity and the most important basic program parameters are
verified for plausibility. In the event of an error, the basic program outputs an error identifier
to the diagnostic buffer and switches the PLC to STOP.
A warm restart is not provided, i.e., following system initialization, the operating system runs
organization block OB 100 and always commences cyclic execution at the start of OB 1.
Synchronization
The PLC is synchronized with the HMI and NCK during power up.
Sign of life
After a proper initial start and the first complete OB1 cycle (initial setting cycle) the PLC and
NCK continuously exchange sign of life signals. If the signoflife signal from the NCK fails to
arrive, the PLC/NCK interface is neutralized and the signal "NCK CPU ready" in DB 10 is set
to zero.
2.7.3
Cyclic operation (OB1)
General
The NCK PLC interface is processed completely in cyclic mode. From a chronological
viewpoint, the basic program runs ahead of the user program. In order to minimize the
execution time of the basic program, only the control/status signals are transmitted cyclically;
transfer of the auxiliary functions and G functions only takes place on request.
The following functions are performed in the cyclic part of the basic program:
• Transmission of the control/status signals
• Distribution of the auxiliary and G functions
• M decoding (M00 - M99),
• M, S, F distribution
• Transmission of the machine control panel signals via the NCK (on the 840D only)
• Acquisition and conditioning of the user errors and operating messages.
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.7 Structure and functions of the basic program
Detailed description
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents