Detailed description
2.12 Block descriptions
MCP/HHU monitoring (840D)
The following alarms are displayed at HMI in cases of errors for the communication with the
machine control panel (MCP):
• 400260: MCP 1 failure or
• 400261: MCP 2 failure
• 400262: HHU failure
In this case, the input signals from the MCP or from the handheld unit (MCP1In/MCP2In or
BHGIn) are reset to 0. If it is possible to resynchronize the PLC and MCP/HHU,
communication is resumed automatically and the error message reset by the GP.
840D example call
An example call for the FB 1 in OB 100 appears below. This example is part of the diskette
with basic program for 840D.
ORGANIZATION_BLOCK OB 100
VAR_TEMP
END_VAR
BEGIN
//INSERT USER PROGRAM HERE
END_ORGANIZATION_BLOCK
106
OB100_EV_CLASS :
OB100_STRTUP :
OB100_PRIORITY :
OB100_OB_NUMBR :
OB100_RESERVED_1 :
OB100_RESERVED_2 :
OB100_STOP :
OB100_RESERVED_3 :
OB100_RESERVED_4 :
OB100_DATE_TIME :
CALL FB 1, DB 7 (
MCPNum :=
MCP1In :=
MCP1Out :=
MCP1StatSend :=
MCP1StatRec :=
MCP1BusAdr :=
MCP1Timeout :=
MCP1Cycl :=
NC-CyclTimeout :=
NC-RunupTimeout :=
BYTE ;
BYTE ;
BYTE ;
BYTE ;
BYTE ;
BYTE ;
WORD ;
WORD ;
WORD ;
DATE_AND_TIME;
1,
P#E0.0,
P#A0.0,
P#A8.0,
P#A12.0,
6,
S5T#700MS,
S5T#200MS,
S5T#200MS,
S5T#50S);