Siemens SINUMERIK 840D sl Function Manual page 1288

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.3 Starting up hardware configuration of PLC CPUs
2.3
Starting up hardware configuration of PLC CPUs
General procedure
The hardware configuration for the PLC CPUs used in the NCU7x0, including other
components of the NCU (NCK, CP, HMI, drive), must be defined via STEP 7. Proceed as
follows in STEP7:
1. Create a new project (File, New, Project)
2. Insert, Hardware, SIMATIC 300 station
3. Select the SIMATIC 300 station with the mouse
4. right mouse button, open object
5. An appropriate SINUMERIK component is selected from the hardware catalog
6. I/Os are to be extended from the hardware catalog of STEP 7
Prerequisites
In order to be able to select SINUMERIK components from the hardware catalog, you must
run the Toolbox setup program first ("Hardware expansions for STEP7" and "Starter"). The
current version of the hardware expansion for STEP7 can also be found under eSupport.
Example of current hadrware allocations PLC to NCU
Table 2-1
Hardware expansions
NCU
SINUMERIK 840D NCU
710.1
SINUMERIK 840D NCU
720.1
SINUMERIK 840D NCU
730.1
SINUMERIK 840Di sl with
MCI2
14
The HW-Config is now started
"SIMATIC 300 \ SINUMERIK \ 840D sl".
The addresses for the I/O modules can be changed, if needed.
MLFB
6FC5 371-0AA00-0AA0
6FC5 372-0AA00-0AA0
6FC5 373-0AA00-0AA0
6FC5 222-0AA02-1AA0
Comparable
SIMATIC CPU MLFB
included
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Selection from STEP7 hardware
catalog
NCU710.1
STEP 7 V5.3 SP2 and higher
and Toolbox 840D sl 01.01.00)
NCU720.1
STEP 7 V5.3 SP2 and higher
and Toolbox 840D sl 01.01.00)
NCU730.1
STEP 7 V5.3 SP2 and higher
and Toolbox 840D sl 01.01.00)
840Di with PLC317-2 DP
STEP 7 V5.3 SP2 and higher
and Toolbox 840D sl 01.02.00)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents