Siemens SINUMERIK 840D sl Function Manual page 1244

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.12 Block descriptions
Description of the formal parameters
The table below shows all formal parameters of the "HPU_MCP" function.
Signal
BAGNo
ChanNo
2.12.28.2 MCP selection signals to the user interface
Operating modes and machine functions
Source:
MCP key
AUTOMATIC
MDA
JOG
REPOS
REF
TEACH IN
INC 1 ... 10 000, INC Var. (starting from SW
5)
Source:
MCP key
INC 1 ... 10 000, INC Var. (till SW 4)
INC 1 ... 10 000, INC Var. (till SW 4)
INC 1 ... 10 000, INC Var. (till SW 4)
Source:
MCP key
INC 1 ... 10 000, INC Var. (till SW 4)
260
Type Type
Value range
I
BYTE
0 - b#16#0A
and
b#16#10 - b#16#1A
I
BYTE
0 - B#16#0A
Remark
No. of mode group to which the mode signals
are transferred.
BAGNo >= b#16#10 means access to the
second machine control panel.
Channel no. for the channel signals
Destination:
Interface DB (parameter ModeGroupNo)
representation for mode group 1
DB11, ... DBX0.0
DB11, ... DBX0.1
DB11, ... DBX0.2
DB11, ... DBX1.1
DB11, ... DBX1.2
DB11, ... DBX1.0
DB11, ... DBB2, Bit 0 to 5
Destination:
Interface DB (parameter ChanNo)
DB21, ... DBB13, Bit 0 to 5
DB21, ... DBB17, Bit 0 to 5
DB21, ... DBB21, Bit 0 to 5
Destination:
Interface DB (6-axis DB)
DB31, ... DBB5, Bit 0 to 5
Basic logic functions: PLC Basic program powerline (P3 pl)