Siemens SINUMERIK 840D sl Function Manual page 1182

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.12 Block descriptions
Declaration of the function
FUNCTION FC 9 : VOID
//NAME :ASUP
VAR_INPUT
END_VAR
VAR_OUTPUT
END_VAR
VAR_IN_OUT
END_VAR
Description of formal parameters
The table below lists all formal parameters of the ASUB function.
Signal
Start
ChanNo
IntNo
Active
Done
Error
StartErr
Ref
198
Start:
BOOL ;
ChanNo:
INT ;
IntNo:
INT ;
Active:
BOOL ;
Done :
BOOL ;
Error :
BOOL ;
StartErr:
BOOL ;
Ref:
WORD ;
Type Type
I
BOOL
I
INT
I
INT
A
BOOL
A
BOOL
A
BOOL
A
BOOL
I/O
WORD
Value range
Remark
1 - 10
No. of the NC channel
1 - 8
Interrupt No.
1 = Active
1 = ASUB completed
1 = Interrupt switched off
1 = Interrupt number not assigned or
deleted
Global variable
1 word per FC 9 (for internal use)
(MW, DBW,..)
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents