Siemens SINUMERIK 840D sl Function Manual page 682

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.7 Program operation mode
Example for call of operator panel reset
For MD20108 $MC_PROG_EVENT = 'H04'
PROC PROG_EVENT DISPLOF
N10 DRFOF
N20 M17
Start with RESET key
The part program is automatically started with the RESET key, whose name is there in
In MD11620 $MN_PROG_EVENT_NAME (program name of PROG_EVENT)
and was saved in one of the following directories
/_N_CUS_DIR/
/_N_CMA_DIR/
/_N_CST_DIR/
or the program
_N_PROG_ENENT_SPF (default).
Control with MD PROG_EVENT_IGN_INHIBIT
If the following machine data settings exist:
CHANDAT(3)
$MC_PROG_EVENT_IGN_INHIBIT= 'H04F'
$MC_PROG_EVENT_MASK= 'H04F'
The program started with the RESET key is executed right up to the end independently of a
possibly set read-in disable.
Note
Block search (SSL):
By setting
MD11450 $MN_SEARCH_RUN_MODE Bit 1 = TRUE (Search parameterization)
The automatic ASUP start after SSL from /_N_CMA_DIR/_N_PROG_EVENT_SPF is
implicitly activated with the changing of the last action block.
For further explanation, refer to "Automatic start of an ASUB after block search" in the
"Program Test" section.
For further explanation of power up of the control, see
References:
/IADC/ Commissioning Manual; Chapter "Activation and Power-up".
124
Basic logic functions: Mode group, channel, program operation, reset response (K1)
;
Deactivate DRF offsets
Function Manual, 11/2006, 6FC5397-0BP10-2BA0