Detailed description
2.7 Structure and functions of the basic program
Relevant parameters (FB 1)
MCP
MCPNum=1 or 2 (number of MCPs)
MCP1In
MCP1Out
MCP1StatSend
MCP1StatRec
MCP1BusAdr
MCP1Timeout (n.r.)
MCP1Cycl (n.r.)
MCPMPI = FALSE
MCP1Stop
MCP1 NotSend
MCPBusType = b#16#55 (via CP 840D sl)
MCPSDB210= FALSE
MCPCopyDB77 = FALSE
An error entry is also made in the PLC alarm buffer for timeouts. resulting in the following
error messages on the HMI:
• 400260: MCP 1 failure
• 400261: MCP 2 failure
• 400262: HHU failure
An MCP or HHU failure is detected immediately after a cold restart even if no data have yet
been exchanged between the MCP/HHU and PLC.
The monitoring function is activated as soon as all components have signaled "Ready" after
powerup.
70
or
MCP2In
MCP2Out
MCP2StatSend
MCP2StatRec
MCP2BusAdr
MCP2Timeout (n.r.)
MCP2Cycl (n.r.)
MCP2Stop
MCP2 NotSend
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
HHU
HHU = 5 (via CP 840D sl)
BHGIn
BHGOut
BHGStatSend
BHGStatRec
BHGInLen (n.r.)
BHGOutLen (n.r.)
BHGTimeout (n.r.)
BHGCycl (n.r.)
BHGRecGDNo
BHGRecGBZNo (n.r.)
BHGRecObjNo (n.r.)
BHGSendGDNo (n.r.)
BHGSendGBZNo (n.r.)
BHGSendObjNo (n.r.)
BHGMPI = FALSE
BHGStop
BHG NotSend