Siemens SINUMERIK 840D sl Function Manual page 1137

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Error identifiers
If it was not possible to execute a job, the failure is indicated by "logic 1" on status parameter
error. The error cause is coded at the block output State:
State
WORD H
0
0
0
0
0
0
0
0
0
0
Configuration steps
To be able to read a GUD variable, its name must be stored in a string variable. The data
block with this string variable must be defined in the symbol table so that the "Addr"
parameter can be assigned symbolically for FB GETGUD. A structure variable can be
defined optionally in any data area of the PLC to receive the variable pointer (see
specification in following example).
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Meaning
WORD L
1
Access error
2
Error in job
3
Negative
acknowledgment, job not
executable
4
Data areas or data
types do not tally
6
FIFO full
7
Option not set
8
Incorrect target area (SD) RD may not be local data
9
Transmission occupied
10
Error in addressing
11
Address of variable
invalid
Detailed description
2.12 Block descriptions
Note
Incorrect compilation of Var. in a job
Internal error, any help:
NC RESET
Check data to be
read in RD
Job must be repeated,
since queue is full
BP parameter "NCKomm" is not set
Job must be repeated
Unit contains value 0
Check Addr (or variable name), area,
unit