Siemens SINUMERIK 840D sl Function Manual page 1347

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Relevant parameters (FB 1)
MCP-device identification
Input
IdentMcpBusAdr
IdentMcpBusProfilNo
IdentMcpBusType
IdentMcpStrobe
IdentMcpBusProfilNo
MCP, BHG, HT8, HT2
Direct control keys, such as OP08T, OP12T
IdentMcpType (Mcp-Type)
no device connected
MCP 483C IE (Compact)
MCP 483C IE
MCP 310
MCP OEM
MCP DMG
HT8
TCU_DT (Direct control keys)
MCP_MPP
HT2
OP08T (direct control keys)
840D: Profibus connection
With an MCP Profibus connection, these components must be considered in the STEP 7
hardware configuration. The MCP may only be interfaced with the standard DP bus on the
PLC (not on MPI/DP). The addresses must be stored in the input and output log range.
These start addresses must also be stored in the pointer parameters of the FB1. The FB1
parameters listed below are used for further parameterization.
There is no Profibus variant of the HHU. For this reason, an Ethernet connection is shown
for the HHU in this figure. The Profibus slave address must be stored in the parameter
"MCP1BusAdr" and "MCP2BusAdr". Enter the pointer to the configured diagnostic address
(e.g., P#A8190.0) in "MCPxStatRec".
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.7 Structure and functions of the basic program
Output
IdentMcpType
IdentMcpLengthIn
IdentMcpLengthOut
Detailed description
Input parameters e.g. OP08T
Values in direct control keys
IdentMcpBusAdr = TCU-Index
IdentMcpBusProfilNo = Value 1
IdentMcpBusType = Default value
Value
B#16#0
B#16#1
0
B#16#80
B#16#81
B#16#82
B#16#83
B#16#84
B#16#85
B#16#86
B#16#87
B#16#88
B#16#89
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents