14
Fold the ribbon cable near the connector to align it with the J2 pins on
the display board, ensuring that the notch on the ribbon cable is facing
toward the display board. Carefully work the ribbon cable connector
onto the J2 pins until firmly seated. Route the cable flat beside the
power supply board, gathering excess cable under the display. Be
careful not to press the cable beneath the alignment posts or studs of
the base. See Figure 41 on page 118.
Note: Do not allow R5 on the power supply board to become bent
during this procedure.
15
Replace the base. If the telephone is equipped with an MPDA or MCA,
reconnect the data cable to the base telephone jack and replace the
footstand (ensuring that the MPDA or MCA cable does not get pinched
between the base and the footstand). Make sure the footstand is firmly
seated in the base.
Note: Place the label supplied with the display on the outside of the
bottom cover of the telephone. This allows proper identification and
tracking of the option level of the set.
16
Tighten all screws, reconnect all cords, and place the telephone in the
normal operating position.
17
Perform the self-test (see) and acceptance test procedures. See
LD 31 in the Software Input/Output Guide Administration
(553-3001-311)
External Alerter Board
Use this procedure to add an External Alerter Board to the M2006, M2008,
M2216ACD, or M2616 telephone. See Figure 42 on page 124 for
information on hooking up the third-party External Alerter device.
Add-on modules
Telephone and Attendant Console Installation
Page 121 of 144