Converting an existing SSC (NTDK20)-based cabinet or
chassis to an IPMG
The CS 1000 software conversion process automatically creates an IPMG for
each existing cabinet and chassis on the source system. For example, on a
CS 1000M cabinet solution with three cabinets configured, the conversion
process creates three IPMGs in LD 97 and the default IPMG numbers are as
follows:
1
2
3
Refer to Table 1 on
information.
Creating the RMD
The first step in the process of converting a Cabinet or Chassis to an IPMG is
to create the RMD. Use the following procedure to create a CP PM Call
Server Software RMD.
Procedure 7
Creating the CP PM Call Server Software
1
2
Communication Server 1000E Upgrade
Superloop 000 Shelf 0;
Superloop 000 shelf 1, and;
Superloop 004 shelf 0.
page 29
IMPORTANT!
When upgrading from an SSC, which support 30 TDS
and 30 CONF, it is important to note that the MGC can
support 60 of each across two TDS loops and two CONF
loops.
Navigate to the Temp folder on your local PC (or the folder into which you
downloaded the CP PM Call Server Load zip file).
Unzip the Call Server Software Load zip file.
This results in:
parent directory (cf:\)
six child directories (plus other required loadware files)
Option 11C Chassis to Communication Server 1000E
Installing the software
for SIPE cabinet/chassis to IPMG conversion
Page 81 of 228