Nortel 1000E Upgrade page 109

Option 11c chassis upgrade
Table of Contents

Advertisement

Procedure 11
Configuring the MGC on the Call Server
1
>LD 97
SCSYS000
MEM AVAIL: (U/P): 103979814
TOT: 104269820
REQ
TYPE supl
SUPL
SUPL
000
004
008
096 ---- ---- VIRTUAL -- - -
100 ---- ---- VIRTUAL -- - -
104 ---- ---- VIRTUAL -- - -
112 ---- ---- VIRTUAL -- - -
REQ
TYPE supl
SUPL 0
SLOT
SUPT ipmg
IPR0 <Elan IP address of the shelf 0 MGC card>
IPR1 <Elan IP address of the shelf 1 MGC card>
IPMG_TYP0 mgc
ZONE0 1
IPMG ZONE CHANGE
Communication Server 1000E Upgrade
Note: This procedure may be performed through Element Manager
following the installation of the Signaling Server. To configure an IPMG
using Element Manager see Procedure 26 on
Log into LD 97 to configure the MGC that will register to the call server:
prt
SUPT SLOT XPEC0
IPMG ---- -- - - -- - -
IPMG ---- -- - - -- - -
IPMG ---- -- - - -- - -
chg
**** ALL VWG CHANNELS MUST BE OUTED AND RECONFIGURED AFTER
DES0
-CE
Installing the software
USED U P: 230475 59531
XPEC1
IPMG
001
002
003
005
006
--- --- - --- ----------
--- --- - --- ----------
--- --- - --- ----------
--- --- - --- ----------
End of Procedure
Option 11C Chassis to Communication Server 1000E
Page 109 of 228
page
204.
ZONE0/1
IPR0/1
---
----------
---
----------
---
---------
004
---
--------
---
---------
---
------------

Advertisement

Table of Contents
loading

Table of Contents