Nortel 1000E Upgrade page 66

Option 11c chassis upgrade
Table of Contents

Advertisement

Page 66 of 228
Installing CS 1000E hardware
NN43041-465
Standard 01.04
To allow for ease of cabling, the CP PM call server may be placed in slots
1 through 4 of the chassis. The CP PM Signaling Server may be placed
in slots 1 through 4 (see Figure 6 on
necessary.
If utilizing the Campus Redundancy High Availability Call Server
option, place the two CP PM call servers in separate Chassis' to allow for
increased survivability.
Figure 5 shows an existing Option 11C Chassis call server with the SSC card.
Once the upgrade is complete, a typical SA Chassis system will resemble
Figure 6 on
page 67
signaling server in the main chassis. The additional media gateways would
then contain MGC cards only for an SA configuration.
Figure 5
Option 11C Chassis call server
July 2007
with an MGC in slot 0, and a CP PM call server and
page
67) or in another chassis if