Nortel 1000E Upgrade page 217

Option 11c chassis upgrade
Table of Contents

Advertisement

Network check
Checking the status of the HSP ports
Communication Server 1000E Upgrade
Appendix A: Upgrading to a High Availability system
As the main chassis has already been built in previous chapters, the steps
required to upgrade to an HA system are:
1
Pick an empty card slot and insert CP PM card into that slot
2
Set the ID of the new call server to core 1
3
Install software (as performed in "Installing the software" on
4
Run LD 137 on the active call server
5
Perform HSP tests and connect the two call servers.
For more information on upgrading to High Availability, refer to the
following NTPs:
Communication Server 1000E: Overview (NN43041-110)
Communication Server 1000E: Planning and Engineering
(NN43041-220)
Communication Server 1000E: Installation and Commissioning
(NN43041-310)
Communication Server 1000E Upgrades (NN43041-458)
Use the LD 137 STAT HSP command to check the status of the HSP. The
following is a sample output of the STAT HSP command.
LD 137
.stat hsp
HSP LINK CARRIER: OK
Auto Negotiation: Enabled
Auto Negotiation Completed: YES
Actual Line Speed: 1000 Mbps
Actual Duplex Mode: Full Duplex
LCS HSP STATE is UP
Ethernet (gei unit number 1):
Internet address: 127.2.0.2
Broadcast address: 127.255.255.255
Option 11C Chassis to Communication Server 1000E