Nortel 1000E Upgrade page 30

Option 11c chassis upgrade
Table of Contents

Advertisement

Page 30 of 228
TN mapping
Table 2
IP phone TN mapping
CS 1000S/M
Slot
61-64
0-31
65-68
0-31
69-72
0-31
73-76
0-31
77-80
0-31
81-84
0-31
85-88
0-31
NN43041-465
Standard 01.04
to it following the software conversion process. IPMG 000 0 can be used as
an IPMG once hardware is added to the system and the applicable database
configurations are complete.
Minimum software release
The conversion process can be applied to the database of existing small
systems provided that the small system has a minimum software version of
23.10.
The following tables map the small system TNs to the CS 1000E TNs (large
system TNs). The conversion feature maps the SIPE TNs to CS1000E TNs
on the IPMGs.
IP phone TN mapping
When converting from small systems (Option 11C, MG1000B, CS 1000M or
CS 1000S) to a CS 1000E CP PM system, the slot and unit number is mapped
to the loop, shelf, card, and unit number as shown in Table 2. Because these
TNs map from a "small system" TN format to a "large system" TN format,
the IP sets do NOT require reprogramming with a new TN.
Unit
Loop
96
100
104
108
112
96
100
July 2007
CS 1000E CP PM
Shelf
0
1-4
0
1-4
0
1-4
0
1-4
0
1-4
1
1-4
1
1-4
Card
Unit
0-31
0-31
0-31
0-31
0-31
0-31
0-31

Advertisement

Table of Contents
loading