INSTRUMENTATION
6. Turn ignition switch to RUN.
7. Indicator needle of gauge being tested must read at position B. If not, replace gauge.
Position B (Typical)
Battery Gauge
TESTING
1. Remove cables from battery and fully charge battery.
2. Connect negative (–) jumper lead from battery to gauge terminal G (GND).
3. Connect positive (+) jumper lead from battery to gauge terminal I or +12 V.
Typical
4. Check gauge reading; if not as shown replace gauge.
Typical