Seawater Pickup Pump - Mercury MerCruiser MCM 454 Mag MPI Service Manual

Table of Contents

Advertisement

SEAWATER COOLED MODELS
3. Check drain plug and lens cover bolts. Tighten securely. Do not overtighten cover bolts
or cover may warp and leak water into boat.
4. Open seacock, if equipped.

Seawater Pickup Pump

Output Test
If an overheating problem exists, use this test to determine if a sufficient amount of water
is being supplied to cool the engine.
IMPORTANT: The following information should be observed before proceeding with
test:
BOAT MUST BE IN THE WATER FOR THIS TEST. This test CANNOT BE performed
with a flush-test device and water hose.
The ability of this test to detect a problem is greatly dependent upon the accuracy
with which it is performed. An error in setting the engine RPM, timing the test or
measuring the water output will affect the overall accuracy of the test and may
produce misleading results. To help ensure accurate results, a shop tachometer
with an error of less than 5% should be used. The boat tachometer definitely
should not be used as its accuracy is questionable. A stop watch should be used
to time the duration of the test to help ensure that the accuracy is maintained
within one second. An 8 qt. (7.6 L) or larger capacity container should be used to
measure water output.
Due to the manner in which this test is performed, it may not be possible to detect
a marginal condition or a high-speed water pump output problem.