SERVICE MANUAL NUMBER 23
Throttle Cable Installation and Adjustment
MPI MODELS (EXCEPT 7.4L MPI)
1. Place remote control handle(s) in neutral idle position.
IMPORTANT: Be sure that cable is routed to avoid sharp bends and/or contact with
moving parts. DO NOT fasten any items to throttle cable. Outer cable must be free to
move when cable is actuated.
2. Remove flame arrestor.
NOTE: If boat is equipped with Quicksilver Zero Effort Controls, the throttle cable mounting
stud must be in the outer hole on the throttle lever.
Index
90-861326--1 MARCH 1999
Downloaded from
https://needmanual.com/
MCM MODELS - BRAVO AND BLACKHAWK DRIVES WITH DRIVESHAFT EXTENSION
a
454 and 502 Mag MPI Shown
a -
Flame Arrestor
b -
Screws
c -
Vent Hose
a -
Position for Zero Effort Controls
c
75113
a
b
75142
73855