b. Front lift motor access method, go to
page 55.
WARNING: Keep hands and appendages clear of the incline platform assembly
before switching power ON. Switching power ON will cause the incline platform to
move to the level "0" Home position.
3. Measure the lift motor calibration distance between the top of the extension tube nut
and the bottom of the lift motor actuator jackscrew housing. Verify that the distance is
within the specified limits specification limit 1 1/8 in - 1 3/16 in (2.8 cm - 3.0 cm) (incline
level set to "0"):
a. If the distance is within the specified limit, calibration is not required. Go to Oper-
ation Verification, see
"Front lift platform assembly access" on
"Operation Verification" on
4 Adjustment Procedures
Lift Motor Calibration
page 52.