7. P10, P20, and P30 consoles
a. Clear the Error Log of any stored error codes: Hold down PAUSE to access the
Error Log > select OK to view error codes, and then hold down QUICK START to
clear the Error Log of all error codes.
b. Clearing the Error Log resets the
status light is blue and the MC status light is green.
8. P62, P80, and P82 consoles
a. Reset the ASL and MC status lights: Select Operating Condition > press Reset
softkey to reset the ASL and MC status lights. Verify the following Maintenance
menu parameters:
Recommended Action: None
l
Operating Condition: Normal
l
Active Status Light: Solid Blue
l
9. Verify that the MC status light is now "green" and the ASL light is "solid blue".
10. Exit service mode.
11. Press QUICK START to start a manual workout. Make sure the fan is running, that the
air flows into the MC housing, and there are no error code 14 events.
Note:The fan will only run after the running belt is moving.
12. Reinstall the hood cover, see
13. Do the Operation Verification tests (see
to service.
1
Active Status Light: Service and maintenance status light.
1
ASL
and MC status lights. Verify that the ASL
"Hood Cover Replacement" on
"Operation Verification" on
5 Replacement Procedures
Motor Controller Fan Replacement
page 60.
page 16) and return