Precor Experience 700 line Series Service Manual page 110

Base, 120 vac and 240 vac
Hide thumbs Also See for Experience 700 line Series:
Table of Contents

Advertisement

Review entire procedure before starting.
Removal Instructions
1. Switch the power OFF and
2. Remove the MC, see
3. Use a #2 Philips screwdriver to remove the MC top cover
4. Use a small standard screwdriver to release the four mounting tabs and carefully lift the
MC top cover from the main housing. Disconnect the power cable connector and
remove the top cover. Retain fastener for installation.
5. Use a #2 screwdriver to remove the four fan fasteners and remove the fan grill
Retain grill and fasteners for installation.
6. Carefully lift the fan
nector through the cable routing opening while removing. Discard the fan.
Installation Instructions
1. Make sure that the replacement fan is the most current part number
(PPP000000304461101), see service bulletin SB.TRM.20161014.
2. The fan must be installed so the air flow is directed into the MC housing. Install the fan
so that the embossed air flow indicator arrow points into the MC housing. If replacing
the older fan with the newer fan, the new fan cable routing has changed. Feed the
power cable thru the right cable housing opening (not the left opening) and install the
new fan.
1
Disconnect a device power cord plug or cable connector from the power receptacle or outlet.
1
unplug
the power cord.
"Motor Controller (MC) Replacement" on
and remove from top cover
5 Replacement Procedures
Motor Controller Fan Replacement
page 89.
screw fastener.
. Guide the power cable and con-
.
Page 102

Advertisement

Table of Contents
loading

This manual is also suitable for:

Experience trm700-16