Siemens SINUMERIK 840D sl Programming Manual page 491

Job planning
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Note
If no tolerance values have been programmed, the $A variables will not be differentiated
sufficiently to distinguish potential differences in the tolerances of the individual functions,
since they can only declare one value.
Circumstances like this can occur if the machine data and the setting data set different
tolerances for compressor functions, smoothing and orientation smoothing. The variables
then return the greatest value prevailing with regard to the currently active functions.
if, for example, a compressor function is active with an orientation tolerance of 0.1° and
ORISON orientation smoothing with 1°, the $AC_OTOL variable will return the value "1". If
orientation smoothing is deactivated, only the value "0.1" will remain to be read.
● Without preprocessing stop in the part program via system variables:
Note
If no tolerance values have been programmed, the $P variables will return the value "-1".
Job Planning
Programming Manual, 03/2013, 6FC5398-2BP40-3BA1
10.11 Programmable contour/orientation tolerance (CTOL, OTOL, ATOL)
$AA_ATOL[<axis>]
$P_CTOL
Programmed contour tolerance
$P_OTOL
Programmed orientation tolerance
$PA_ATOL
Programmed axis tolerance
Axis tolerance effective when the current main run
record was preprocessed.
If no contour tolerance is active,
will return the contour tolerance divided by the
axis>]
root of the number of geometry axes.
If an orientation tolerance and an orientation
transformation are active
will return the orientation tolerance divided by
axis>]
the root of the number of orientation axes.
Path traversing behavior
$AA_ATOL[<geometry
$AA_ATOL[<orientation
491

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents