<file name>
<start line>
<number of lines>
Job Planning
Programming Manual, 03/2013, 6FC5398-2BP40-3BA1
:
Name of the file to be read (call-by-value parameter)
Type:
STRING
The following points should be noted when specifying the file name:
 The specified file name must not contain any blank spaces or
control characters (characters with ASCII code ≤ 32), otherwise
the
READ
allowed".
 The file name can be specified with path data and file identifier.
– Path data
Path data must be absolute, i.e. start with "/".
If a path is not specified, the file is searched for in the current
directory (= directory of selected program).
– File identifier
If the file name does not contain a domain identifier ("_N_"), it is
added accordingly.
If the fourth-last character of the file name is an underscore "_",
the next three characters will be interpreted as the file identifier.
In order to be able to use the same file name for all file
commands, e.g. via a STRING type variable, only the _SPF
and _MPF file identifiers may be used.
If there is no "_MPF" or "_SPF" identifier, the file name is
automatically completed with _MPF.
 The file name length can be up to 32 bytes, the path length up to
128 bytes.
Example:
"PROTFILE"
"_N_PROTFILE"
"_N_PROTFILE_MPF"
"/_N_MPF_DIR_/_N_PROTFILE_MPF/"
:
Start line of the section of the file to be read (call-by-value parameter)
Type:
INT
Value:
0
1 to n
:
Number of lines to be read (call-by-value parameter)
Type:
INT
command will be canceled with error code 1 "Path not
Reads the number of lines specified with the
<number of lines>
the file.
Number of the first line to be read.
Flexible NC programming
1.20 Read lines in the file (READ)
parameter before the end of
147