Testing the Lift Circuit–Lift Cylinder Internal Leakage (5610-D)
g216146
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
Perform the lift cylinder internal leakage test if you identify a cutting reel raise and
lower problem. This test determines if the lift cylinder being tested is damaged.
The lift cylinders must be tested individually.
Note: The raise/lower circuit operation can be affected by the lift cylinder
binding, extra weight on the cutting reel, and/or binding of the lift components.
Ensure that these items are checked before continuing with the lift cylinder
internal leakage test.
Figure 138
Page 6–139
Hydraulic System: Testing the Hydraulic System